Indian Journal of Pharmacology Home 

RESEARCH ARTICLE
[View FULLTEXT] [Download PDF]
Year : 2012  |  Volume : 44  |  Issue : 1  |  Page : 41--45

The peak bispectral index time cannot predict early phase propofol pharmacodynamics with effect site-controlled infusion algorithm

Jing Niu1, Shan-Juan Wang2, Ma-Zhong Zhang1, Yong-Lei Huang2, Lin Song2, Qing Yu2, Wen-Yin Xu1 
1 Department of Anesthesiology and Pediatric Clinical Pharmacology Laboratory, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China
2 Department of Anesthesiology, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China

Correspondence Address:
Ma-Zhong Zhang
Department of Anesthesiology and Pediatric Clinical Pharmacology Laboratory, Shanghai Children«SQ»s Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai
China

Objectives: The plasma-effect site equilibration rate constant (ke0) of propofol was determined with peak bispectral index (BIS) time (T PEAK ) in our previous study. The present study has been conducted to evaluate the ke0«SQ»s performance with effect site-controlled infusion algorithm. Materials and Methods: Forty unpremedicated patients were randomized to group TE1 (Schnider«SQ»s pharmacokinetic model with ke0 adapted to T PEAK = 74s) and TE2 (T PEAK = 96s). In stage 1, all patients received propofol with effect-site concentration (Ce) controlled infusion. Once the pump had injected the mass of propofol necessary to achieve pre-set Ce and while the infusion was stopped, target was reset at 0 μg/ml. When BIS returned to 80 or above, then, in stage 2, the patients received plasma concentration controlled infusion for 10 min. The time of loss of responsiveness (LOR) and BIS were recorded. The differences of Ce at the time of LOR, lowest BIS between stages 1 and 2, hysteresis loop were used to evaluate the performance of ke0. Results: In both groups, the calculated propofol Ce at the time of LOR in stages 1 and 2 differed significantly (P<0.01); the mean lowest BIS in stage 1 were significantly higher than those in stage 2 (P < 0.05).The relations of propofol Ce versus BIS revealed the apparent hysteresis loop. Conclusions: The study cannot clinically validate the accuracy of application of ke0 derived from the T PEAK = 74 s of BIS with Schnider propofol pharmacokinetic model.


How to cite this article:
Niu J, Wang SJ, Zhang MZ, Huang YL, Song L, Yu Q, Xu WY. The peak bispectral index time cannot predict early phase propofol pharmacodynamics with effect site-controlled infusion algorithm.Indian J Pharmacol 2012;44:41-45


How to cite this URL:
Niu J, Wang SJ, Zhang MZ, Huang YL, Song L, Yu Q, Xu WY. The peak bispectral index time cannot predict early phase propofol pharmacodynamics with effect site-controlled infusion algorithm. Indian J Pharmacol [serial online] 2012 [cited 2023 Sep 27 ];44:41-45
Available from: https://www.ijp-online.com/article.asp?issn=0253-7613;year=2012;volume=44;issue=1;spage=41;epage=45;aulast=Niu;type=0